Zoeller Homeguard Max water powered backup sump pump system with new improved float valve system.
HOME GUARD MAX
WATER POWERED EMERGENCY BACKUP SUMP PUMP
NEW IMPROVED DESIGN!

DEAN BENNETT SUPPLY
Toll Free : 1-800-621-4291
Smart Phone Dialable

HOME GUARD USES WATER TO PUMP
WHEN THE POWER IS OFF

The Zoeller HOME GUARD MAX backup system operates off your house water system to pump when your sump pump is inoperable.
No electricity is required to have the protection against basement flooding.
The HOME GUARD MAX does not use any water until your regular sump pump fails to do the job.

New Improved Design eliminates the valve that was pushed open by the float on the older HomeGuard unit, with a valve built into a housing that eliminates the failure to open or close.

When power goes out, how will your sump pump keep your basement dry?

Home Guard Max Install Instructions

Zoeller water powered HomeGuard Max is excellent protection against basement flooding.

 
   

The new HomeGuard Max is 38 3/4" high from suction to point of inlet into the discharge line. Unit clamps onto your regular sump pump discharge line, and runs its own discharge to eliminate system combination problems. Suction line offsets 8 1/8" to the side.


HOME GUARD MAX #503   $ 109.95
Only 5 units remain
at this special low clearance price

Typical installation using separate discharge from sump pump.

Pictured above is a typical installation. The HOME GUARD MAX is installed in the basin along side the regular sump pump. The incoming water line connects to the valve and uses 1 gallon of water at 20 psi to remove 2 gallon from the sump basin. When you have higher water pressure, such as 80 psi it pumps out 2 gallons for every 1 gallon from the water supply line.


TOTAL PUMP OUTPUT

WATER PRESSURE
AT INLET WITH
VALVE OPEN &
WATER FLOWING

WATER PUMPED/MINUTE AT VARIOUS HEADS

NO WATER
REMOVED /
NO FLOW

STATIC HEAD IN 1-1/4" IPS or LARGER

GALLONS PER MINUTE
PSI 5 FT 10 FT 15 FT 20 FT 25 FT 30 FT 35 FT 40 FT SHUT OFF HEAD FEET
20 7.7 3.4             14 FT
40 12.7 12.7 7.4 2.0         22 FT
60 19.0 19.0 15.0 11.1 7.1 3.2     34 FT
80 20.0 20.0 20.0 20.0 15.3 10.9 6.4 1.8 42 FT
Pump capacity varies by inlet water pressure, working water pressure, discharge elevation, number of pipe fittings, inlet and outlet hose size, fluid viscosity, water clarity, water temperature, and cleanliness of the inlet screen. NOTE: Some districts may require a reduced pressure principal backflow preventer per ASSE Standard 1013. Check with your local codes.