HEAT TAPE
PRICES

Download Heat Tape in pdf

DEAN BENNETT SUPPLY
PH 1-800-621-4291
Smart Phone Dialable


Industrial grade heat tape is approved for fire protection systems.

Frostex 3 watts per foot heat tape for pipe freeze protection.
Frostex  3 watt per foot Heat Tape

FROSTEX Information & Chart

Download Frostex Heat Tape in pdf


Frostex Heat Tape
120V 3 Watt per foot
Maximum 50' cable
Use on up to 2" Pipe

Description Price
Frostex Heat Tape $ 2.23 ft
Frostex Plug End Kit $ 17.00
Frostex Application Tape $ 12.25
Frostex 100' Roll Heat Tape $ 223.00
Frostex 50' Truck Pak
w/ 2 plug kits
$ 167.00

Wintergard 3 watts per foot heat tape for keeping pipes from freezing.
WinterGard 3 Watt 120V #H-311 Heat Tape

WinterGard Information & Chart

Download 3 watt Wintergard Heat Tape in pdf

H908 Plug Kit Installation Instructions in pdf


WinterGard Heat Tape
120V 3 Watt per foot
Maximum 250' cable
Use on up to 8" Pipe

Description

Price

WinterGard H-311 Heat Tape $ 3.15 ft
WinterGard Plug Kit w/GFI $ 59.25
WinterGard Tape & Labels $ 13.75
Gel Filled End Kits ( 2 ends ) $ 13.25

Wintergard Plus 6 watts per foot heat tape for pipe freeze protection.
WinterGard 6 Watt H-611 120V Heat Tape

WinterGard Plus
Information & Chart

Download 6 watt Wintergard Heat Tape in pdf

H908 Plug Kit Installation Instructions in pdf


WinterGard Plus Heat Tape
120V 6 Watt per foot
Maximum 200' cable
Use on up to 8" Pipe

Description Price
WinterGard Plus H-611 Heat Tape $ 3.80 ft
WinterGard Plus Plug Kit w/GFI $ 59.25
WinterGard Plus Tape & Labels $ 13.75
Gel Filled End Kits ( 2 ends ) $ 13.25

Wintergard Wet 6 watts per foot heat tape for pipes and roof edge freeze protection.
WinterGard Wet 6 Watt H-612 120V Heat Tape

WinterGard Wet for Roof Installation

WinterGard Wet for Water Pipes

Wintergard Wet Roof & Gutter Tape in pdf

Wintergard Wet Heat Tape for Water Pipes in pdf

H908 Plug Kit Installation Instructions in pdf

Wintergard heat tape construction drawing.

 


WinterGard WET Heat Tape
Self Regulating Heat Cable
120V 6 Watt per foot
Maximum 150' roof / gutter cable
Maximum 200' pipe cable
Use on up to 8" Pipe

Description Price
WinterGard Wet H-612 Heat Tape $ 4.75 ft
WinterGard Wet Plug Kit w/GFI $ 59.25
WinterGard Wet Tape & Labels 13.75
Gel Filled End Kits ( 2 ends ) $ 13.25
10 Pack Roof Clips H-913 $ 16.50
50 Pack Roof Clips H-914 $ 55.00
Down Spout Hanger Brackets
H-915
$ 15.00
Splice & Tee Kit ( Waterproof )
H-910
$ 15.25

WinterGard Wet self regulating heating cable system eliminates icicles and ice dams safely and efficiently. WinterGard Wet heating cable can be cut and spliced to fit the layout of any roofline or gutter installation. Installed on a roof or inside gutters and downspouts, the WinterGard Wet heating tape created a drainage path for melting snow and ice, adjusting the heat output as the ambient temperature fluctuates. When the gutter is dry, the WinterGard Wet automatically cuts back its power output so it won't ever overheat or burn out.

Parallel circuitry allows current to flow between the two bus wires independently at each point along the heating cable.
The conductive polymer heating core regulates its power output in response to the temperature, making it self regulating.
The heating cable is constructed of Nickel-copper bus wires, self regulating conductive core material, insulating jacket, tinned-copper braid, and an outer fluoropolymer jacket.
WinterGard Wet heating cable can be overlapped, cut to length, will not butn out, saves energy because it is self regulating, and will not overheat roofing materials or plastic gutters.
 

PRE-ASSEMBLED HEAT TAPES
READY TO USE HEAT TAPES
Must use a GFI protected circuit with these pre-assembled 120V heat tapes.
 

6' Pre-assembled heat tape for pipe freeze protection. 12' pre-assembled heat tape for pipes and eaves. 24' pre-assembled heat tape for wet locations like roof edges and pipes. 50' pre-assembled heat tape with plug installed ready to use.
Pre-Assembled
Heat Tapes with Plug and
end seal installed.

Choose the size
right for your job.

W516P
6' Heat Tape
W5112P
12' Heat Tape
W5124P
24' Heat Tape
W5150P
50' Heat Tape

These pre-assembled heat tapes are assembled with the 120V plug installed and are ideal for pipes and roof edge where a heat tape is desired to keep snow and ice from building up on roof edges or eaves.
 

  6' #W516P

  6' pre-assembled heat tape approved for wet locations. 120V
power for pipes and eaves. Must use a GFI power circuit.
 

$   67.00
12' #W5112P 12' pre-assembled heat tape approved for wet locations. 120V
power for pipes and eaves. Must use a GFI power circuit.
 
$   85.00
24' #W5124P 24' pre-assembled heat tape approved for wet locations. 120V
power for pipes and eaves. Must use a GFI power circuit.
 
$ 125.00
50' #W5150P 50' pre-assembled heat tape approved for wet locations. 120V
power for pipes and eaves. Must use a GFI power circuit.
 
$ 218.00
SPECIAL ORDER SIZES OF PRE-ASSEMBLED HEAT TAPES
  18' #W5118P
SPECIAL
ORDER
  18' pre-assembled heat tape approved for wet locations. 120V
power for pipes and eaves. Must use a GFI power circuit.
 
$ 104.00
  75' #W5175P
SPECIAL
ORDER
  75' pre-assembled heat tape approved for wet locations. 120V
power for pipes and eaves. Must use a GFI power circuit.
 
$ 308.00
100' #W51100P
SPECIAL
ORDER
100' pre-assembled heat tape approved for wet locations. 120V
power for pipes and eaves. Must use a GFI power circuit.
$ 395.00
         

Roof Top Snow & Ice Sensor Switch
to Turn On Heat Tape to Prevent Buildup

NEW TO OUR STOCK
Wintergard Wet 230V Heat Tape

WinterGard Wet 230V heating cable is a professional-grade, 6 watt per foot, self-regulating electrical heat cable that can be used to protect pipe from freezing, or can be used for roof deicing. The heating cable has a construction of nickel-copper bus wires, a self-regulating conductive core, an insulated jacket, a tinned copper braid and an outer jacket of polyolefin. There are several advantages to the Wintergard wet self-regulating heat tape. It can be overlapped, you can cut it to length without burn out, it saves energy and it will not overheat roofing material or gutters when used to deice your roof.
WinterGard Wet 230V can be used up to 350 feet to protect pipes for temperatures down to 0 degrees. You can also use it for gutters in lengths up to 250 feet. 

WinterGard Wet 230V H-622 #WGWHT230xCUT                                            $ 5.38 ft.

WinterGard H900 Power Connection Kit

The WinterGard H900 Power Connection Kit can be used to hard wire your heat tape to the power supply line. This kit can be used with WinterGard 3 Watt 120V heat tape, WinterGard 6 Watt 120V heat tape, Wintergard Wet 6 Watt 120V heat tape and WinterGard Wet 6 Watt 230V heat tape. Do not use with aluminum feed wires. Kit contains one power connection and one end seal.

WinterGard H900 Power Connection Kit                                                         $ 27.25

Fixed Point Thermostat (40 degree F)

AMCF5  Fixed point Thermostat is factory set for 40 degree F control of heat tape.           $ 166.25

Thermocube Heat Tape Thermostat for controlling power to your heat tape run.

Avoid Cold Weather Problems

Thermo Cube is a device which plugs into a standard GFI protected 120V AC outlet to automatically control turning power on and off for heat tape or stock tank heaters. By plugging the device into the Thermo Cube, when the air temperature reaches 35 degrees F, the Thermo Cube will turn on the power. When the Air temperature gets up to 45 degrees F, the power will turn off. This makes your heat tape more efficient to operate, since you are not having to run the power all the time. According to the manufacturer, you can use the Thermo Cube to control heat tape or stock tank heaters that are rated up to 1800 watts maximum or 15 amps total on 120V GFI protected circuits.

TC3 is 3-1/4" wide and 1-3/8" high and 1" thick, and has place for two 3 prong plugs to plug into it.

TC3     Thermo Cube Heat Tape Thermostat
                                      
$ 23.00

Nema 3 Splice Box for heat tape connection.
H921    $ 138.25

NEMA3 Rain Tight Junction Box H921
$ 138.25

H921 WinterGard 120 V heat tape junction box with ground fault equipment protection, for use with H900 Hard Wire Power Connection Kit. Junction box is rain tight.

Excellent for use with H612 WinterGard Wet heat tape when using on a roof or gutter to make power connection where the potential for getting wet is present.
 

Illustration of using the Nema 3 splice box to connect roof heat tape.

Electronic heat tape temperature controller to control on and off temperature points. $ 137.00  #HTTHERMOSTAT

ELECTRONIC TEMPERATURE CONTROL
for Heat Tape Temperature Control

120V Electronic Temperature Control Electronic Temperature Control unit has a temperature differential range of 1 Degree F to 30 Degrees F. Unit can control temperatures from -30F to 220F, however you will not need the range capabilities of this control for use with heat tape for on your roof or on water pipes.

Electronic Heat Tape Temperature Control


Inside the Pipe Heat Tapes

 

Protect buried water lines
from freezing with
WinterGard
Inside the Pipe Heat Tapes

WinterGard In-Pipe Heat Tapes

Internal heat tape for protecting below ground water pipes.

          Current Controller

New Controller (01/11)          

HOME

Industrial Heat Cable

Download our catalog in pdf format

No Return of Merchandise

Prices effective July 20, 2012